There are two basic types of smoke detectors.
Smoke detector placement in bedroom with ceiling fan.
5 feet away on the ceilin.
If the unit operates off a battery test the detector weekly and replace the battery at least once a year.
Ionization detectors ionization detectors contain radioactive material that ionizes.
While the meticulous installation of smoke detectors has always been crucial.
910 mm horizontal path from the tip of the blade of a ceiling suspended paddle fan nfpa 72 29 8 3 4 8 not always possible.
One bedroom has a ceiling paddle fan in the center of the ceiling.
To give you a definite answer we will take some help from nfpa s.
Where should i place the smoke detector.
In either case install the alarm at least 4 inches 100 mm from where the wall and ceiling meet.
The installation of a smoke detector in a bedroom with a ceiling fan has forced many to ponder whether they will work or not.
When installing an alarm on the ceiling place the alarm as close to the center as possible.
On levels without bedrooms install alarms in the living room or den or family room or near the stairway to the upper level or in both locations.
Like smoke detectors co alarms need to be tested regularly and cleaned as indicated in the manufacturer s use and care booklet.
Adding smoke detectors in the bedrooms of a 50 year old house.
My concern is that the fan will blow away any smoke from the detector.
If you must mount the smoke detector on the wall it should be placed less than 12 inches away from the ceiling.
Read the smoke detector s manual before installing for proper set up.
Smoke alarms should be installed at least 10 feet 3 meters from a cooking appliance to minimize false alarms when cooking.
Mount smoke alarms high on walls or ceilings remember smoke rises.
Choose smoke alarms that have the label of a recognized testing laboratory.
Install smoke alarms inside each bedroom outside each sleeping area and on every level of the home including the basement.
Smoke alarms and smoke detectors shall not be installed within a 36 in.
Smoke alarms installed in the basement should be installed on the ceiling at the bottom of the stairs leading to the next level.
A smoke detector should be installed in every room that will be occupied.
Smoke detectors have always been an absolute necessity and more so nowadays due to the ever increasing fire incidents.
Many smoke detectors are designed to mount to a ceiling but some can also be wall mounted when attaching to a ceiling isn t feasible.
When installing an alarm on the wall the top edge of alarms should be placed between 4 inches 100 mm and 12 inches 300 mm from the wall ceiling line.
Place smoke detectors at least 3 feet from ceiling fans.
Install smoke detectors on the ceiling.